SciELO - Scientific Electronic Library Online

 
vol.77 número3Utilización de tecnología, información, comunicación y aula virtual en la enseñanza de la asignatura de Gerencia en Salud para los médicos residentes de la Facultad de Medicina de la Universidad Nacional Mayor de San Marcos, 2015Multidisciplinariedad en el manejo de enfermedades crónicas índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Anales de la Facultad de Medicina

versión impresa ISSN 1025-5583

Resumen

GOLAC MALEA, Mario; SANDOVAL VEGAS, Miguel  y  MORALES DEL PINO, Jimmy. Comparing creatinine clearance in 24 hour urine and Cockcroft-Gault formula to determine glomerular filtration rate in pregnant women attended in a Lima hospital. An. Fac. med. [online]. 2016, vol.77, n.3, pp.257-262. ISSN 1025-5583.

Glomerular filtration rate (GFR) is calculated by the endogenous creatinine clearance (DCE) in 24-hour urine, with limited collection and difficulties for patients. There are formulas proposed to estimate renal function. Objective. To use the Cockcroft-Gaul formula of glomerular filtration and to compare it with the chemical colorimetric method in pregnant women. Design. Observational, correlational, prospective and transversal study. Setting. Central Laboratory, Sergio Bernales National Hospital, Lima, Peru. Participants. Pregnant women. Methods. Using prior informed consent blood samples and 24-hour urine of 92 pregnant women between November 2015 and January 2016 were processed. The Pearson correlation coefficient was used to compare the DCE results obtained with the Cockcroft­ Gault formula and the serum-24 hours urine. Results. The sample had a normal distribution analyzed by Kolmogorov-Smirnov estimator. The average DCE in 24 hours urine was 73.65 ± 19.85 mL /min, and that obtained by the Cockcroft-Gault formula was 99.82 ± 18.75 mL/min, with t test significant difference in related samples (p <0.000); the correlation between these laboratory methods was low (r = 0.561) in all pregnant women and by trimesters, showing lack of correlation with the coefficient of the Lin correlation-matching (ccc) (p <001) Sensitivity (S) was 0.50, specificity (Sp) 0.591, positive predictive value (PPV) 0.212 and negative predictive value (NPV) 0.881. Conclusions. The DCE obtained by Cockcroft-Gault with the DCE serum-24 hours urine in pregnant women had low correlation (r = [OA to 0.67]) with low levels of S, Sp, PPV and NPV, so it is not recommended for use in pregnant women.

Palabras clave : Cockcroft-Gault Formula; Glomerular Filtration Rate; Pregnant Women; Creatinine Clearance; Renal Function.

        · resumen en Español     · texto en Español     · Español ( pdf )