SciELO - Scientific Electronic Library Online

 
vol.28 número1Traducción y adaptación de la versión al español del Questionnaire on Knowledge, Attitudes and Behaviors related to Oral Health (QKAB-OH) índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista Estomatológica Herediana

versión impresa ISSN 1019-4355

Resumen

ZELADA LADRON DE GUEVARA, Cinthya Cecilia et al. Adaptation of unit coping Co-Cr elaborated with diferent manufacturing techniques and two finishing lines. Rev. Estomatol. Herediana [online]. 2018, vol.28, n.1, pp.7-19. ISSN 1019-4355.  http://dx.doi.org/https://doi.org/10.20453/reh.v28i1.3278.

New technologies have allowed us to migrate from the spin-wax casting technique (CPC) to additive manufacturing such as selective laser fusion (SLM), providing a better marginal and internal adaptation. Objectives: To compare the marginal and internal discrepancies in Co-Cr unit metal copings on two termination lines: chamfer and bevel, made with CPC and SLM, determining which technique had the best marginal and internal adaptation. Material and Methods: We had 4 study groups: CPC chamfer (n=13), CPC bevel (n=13), SLM chamfer (n=13), SLM bevel (n=13). To assess marginal and internal discrepancies, the silicone replica technique was used, a first sectioning was performed in the vestibular-palatine (V-P) and a secondin the mesio-distal (M-D) direction. The cervical, axial and occlusal zones were measured in a stereomicroscope at 40X. Results: Normality assumptions were evaluated with the Shapiro-Wilk test. Statistical analyzes were Student’s t test and U Mann-Whitney test. The less discrepancy marginal was for the SLM chamfer with mean values less than 24.70±10.29 μm in the V-P cut and 21.82±5.94 μm in the M-D cut, followed by the SLM bevel in the P-V cut of 34.12±16.23 μm and in the cut M-D of 35.34±8.91 μm. The CPC bevel in the V-P cut was 27.17±21.11 μm and in the M-D cut of 47.91±16.77 μm and for the CPC chamfer in the V-P cut was 89.65±58.39 μm and in the M-D cut of 91.72±67.13 μm; the difference was statistically significant only for SLM chamfer copings compared to the CPC chamfer. In the internal discrepancy values, no statistical differences were found among the 4 groups. Conclusions: Accord- ing to the descriptive values the best marginal fit was achieved with the SLM chamfer, followed by the SLM bevel, CPC bevel and CPC chamfer. Regarding internal adaptation, the descriptive values were not conclusive enough to decide which technique was better, but a better adaptation was achieved in the axial zone than in the occlusal zone.

Palabras clave : Crowns; adaptation; lasers solid-state.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons