ARTIFON, Everson L.A., COELHO, Flavio, FRAZAO, Mariana et al. Un estudio prospectivo y randomizado comparando el uso de Stents de metal parcialmente cubiertos de plastico versus multistents en el manejo endoscópico de los pacientes con estenosis benignas postoperatorias del ducto biliar en un seguimiento de más de 5 años. Rev. gastroenterol. Perú, ene./mar. 2012, vol.32, no.1, p.26-31. ISSN 1022-5129.

BACKGROUND: Self-expandable metal stents (SEMS) are often used for biliary drainage due to obstruction of neoplastic etiology, with better results than plastic stents, but seldom for biliary drainage of benign etiology. OBJECTIVE: Primary end point: Verify bile duct patency after placement of self-expandable metal and (multiple) plastic stents in patients with benign strictures resulting from bile duct surgery with follow-up above five years. Secondary end point: Evaluate long-term complication rate in patients with metal selfexpandable and plastic stents. RESULTS: Self-expandable stents were placed in 15 patients and multiple plastic stents in 16. Mean age was 45 years with prevalence of female patients in both groups and no statistical difference between groups was observed (SEMS: 66.7%; plastic multistent: 62.5%; p=0.8). Complication rate resulting from stents occurred more often in the metal stent group (40% versus 25%; p=0.37). In the metal stent group, most frequent complications were hemorrhage (n=3; 20%), stent migration (n=2; 13.3%) and perforation (n=1; 6.7%). In plastic multistent group, most frequent complications were perforation (n:2; 12.5%), hemorrhage (n=1; 6.2%) and ulcer (n=1; 6.2%). Long-term patency rate after biliary drainage was higher in the selfexpandable metal stent group, SEMS: 81.67% ± 2.56; CI: 76.47-86.54; plastic multistent: 71.88% ± 2.93; CI: 66.08-77.27. CONCLUSION: The temporary passage of partially covered self-expandable metal stents is a feasible option for patients with benign bile duct strictures.

Palabras llave: Prothesis; Stents; Biliary duct stenosis.

        · resumen en español     · texto en inglés     · pdf en inglés


 

© 2013  Sociedad de Gastroenterología del Perú

Juan Aliaga Nº 204
Lima 17 - Perú
Telf.: 515-264 0015
Fax: 515-264 1400



revista_gastro@terra.com.pe