vol.34 número2Síndromes hereditarios de predisposición al cáncer colorrectal identificados en el Instituto Nacional de Enfermedades Neoplásicas (INEN), Lima, PerúEvaluación de la realización de paracentesis en pacientes cirróticos ingresados a dos servicios de medicina interna de hospitales mediana complejidad índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

  • Não possue artigos citadosCitado por SciELO

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Revista de Gastroenterología del Perú

versão impressa ISSN 1022-5129

Resumo

ROBLES, Christian et al. Surveillance cultures after high-level disinfection of flexible endoscopes in a general hospital. Rev. gastroenterol. Perú [online]. 2014, vol.34, n.2, pp.115-119. ISSN 1022-5129.

Introduction: Flexible endoscopes are instruments with a complex structure which are used in invasive gastroenterological procedures, therefore high-level disinfection (HLD) is recommended as an appropriate reprocessing method. However, most hospitals do not perform a quality control to assess the compliance and results of the disinfection process. Objectives: To evaluate the effectiveness of the flexible endoscopes decontamination after high-level disinfection by surveillance cultures and to assess the compliance with the reprocessing guidelines. Material and methods: Descriptive study conducted in January 2013 in the Gastroenterological Unit of a tertiary hospital. 30 endoscopic procedures were randomly selected. Compliance with guidelines was evaluated and surveillance cultures for common bacteria were performed after the disinfection process. Results: On the observational assessment, compliance with the guidelines was as follows: pre-cleaning 9 (30%), cleaning 5 (16.7%), rinse 3 (10%), first drying 30 (100%), disinfection 30 (100%), final rinse 0 (0%) and final drying 30 (100%), demonstrating that only 3 of 7 stages of the disinfection process were optimally performed. In the microbiological evaluation, 2 (6.7%) of the 30 procedures had a positive culture obtained from the surface of the endoscope. Furthermore, 1 (4.2%) of the 24 biopsy forceps gave a positive culture. The organisms isolated were different Pseudomonas species. Conclusion: High-level disinfection procedures were not optimally performed, finding in 6.7% positive cultures of Pseudomonas species.

Palavras-chave : Disinfection; Endoscopes; Quality control.