SciELO - Scientific Electronic Library Online

 
vol.34 número3Determinantes dietéticos del consumo de zinc en menores de cinco años con retardo del crecimiento en comunidades mayas de GuatemalaMarcadores de infección para hepatitis viral en donantes de sangre de un hospital nacional de Lima Metropolitana índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista Peruana de Medicina Experimental y Salud Publica

versión impresa ISSN 1726-4634

Resumen

ROMERO-RUIZ, Soledad; MIRANDA-ULLOA, Eduardo  y  BRICENO-ESPINOZA, Ronal. Diagnostic performance of the indirect immunofluorescence test for the detection of antibodies against HTLV-1. Rev. perú. med. exp. salud publica [online]. 2017, vol.34, n.3, pp.459-465. ISSN 1726-4634.  http://dx.doi.org/10.17843/rpmesp.2017.343.2635.

The objective of the study was to determine the diagnostic yield of the indirect immunofluorescence (IFI) test for the detection of antibodies against HTLV-1. A diagnostic test evaluation study was performed. HTLV-1-infected MT2 cells and HTLV-1-uninfected K-562 cells were cultured; then these cells were impregnated and fixed in sheets for immunofluorescence and faced to Peruvian sera. A total of 155 sera (80 HTLV-1-positive sera and 75 sera positive for other diseases) from the Peruvian Instituto Nacional de Salud were used. In addition, the parameters of repeatability (intra-laboratory) and reproducibility (in laboratories of the Peruvian coast, mountains and jungle) of the test were evaluated. The IFI test detected the presence of antibodies against HTLV-1 reaching a sensitivity of 98.75% (95% CI: 95.69 - 100.00%), a specificity of 98.67% (95% CI: 95.40 - 100.00%) and the Kappa index was 0.975. There were no false positives or false negatives; however, one undetermined result and one non-specific result were obtained. The test showed 100% qualitative agreement when performing the repeatability and reproducibility. The results obtained are comparable to the reference test. Therefore, the IFI test had a good diagnostic performance and would be useful for the confirmation of HTLV-1.

Palabras clave : Human T-lymphotropic virus 1; Diagnosis; Fluorescent antibody technique; indirect.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons