vol.39 número3Cambios en las características clínicas y desenlaces de pacientes hospitalizados por COVID-19 durante dos años de pandemia: experiencia en un hospital venezolanoAmplificación directa de ADN de Bordetella pertussis purificado de hisopados nasofaríngeos por un método de bajo costo, rápido (60-segundos) y libre de equipos índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

  • Não possue artigos citadosCitado por SciELO

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Revista Peruana de Medicina Experimental y Salud Publica

versão impressa ISSN 1726-4634

Resumo

GOMEZ-HOYOS, Roxana et al. Systematic review of the diagnostic accuracy of thick smear compared to polymerase chain reaction for pregnancy-associated malaria, 2010-2022. Rev. perú. med. exp. salud publica [online]. 2022, vol.39, n.3, pp.302-311.  Epub 30-Set-2022. ISSN 1726-4634.  http://dx.doi.org/10.17843/rpmesp.2022.393.11739.

Objective.

To evaluate the accuracy of thick smear (TS) versus quantitative polymerase chain reaction (PCR) for pregnancy-associated malaria (PAM).

Materials and methods.

We carried out a systematic review of diagnostic tests in nine databases. Methodological quality was evaluated with QUADAS. Sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR) and area under the ROC curve were estimated. Heterogeneity was determined with the Der Simonian-Laird Q method and uncertainty with the weighted percentage of each study on the overall result.

Results.

We included 10 studies with 5691 pregnant women, 1415 placentas and 84 neonates. In the studies with nested PCR (nPCR) and quantitative PCR (qPCR) as the standard, the diagnostic accuracy results were statistically similar, with very low sensitivity (50 and 54%, respectively), high specificity (99% in both cases), high PLR and poor NLR. When nPCR was used, the DOR was 162 (95%CI=66-401) and the area under the ROC curve was 95%, while with qPCR it was 231 (95%CI=27-1951) and 78%, respectively.

Conclusions.

We demonstrated that research on the diagnostic accuracy of TS in PAM is limited. Microscopy showed poor performance in the diagnosis of asymptomatic or low parasitemia infections, which reinforces the importance of implementing other types of techniques for the follow-up and control of malaria infections in pregnant women, in order to achieve the control and possible elimination of PAM.

Palavras-chave : Thick Blood Smears; PCR; Diagnostic Accuracy; Malaria Associated with Pregnancy; Meta-analysis.