SciELO - Scientific Electronic Library Online

 
vol.21 número4Parámetros ecocardiográficos relacionados a hipertensión arterial pulmonar en pacientes con leucemia mieloide crónica en tratamiento con dasatinib índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

  • Não possue artigos citadosCitado por SciELO

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Revista de la Facultad de Medicina Humana

versão impressa ISSN 1814-5469versão On-line ISSN 2308-0531

Resumo

MIRANDA-ULLOA, Eduardo et al. Standardization and validation of a Western Blot for the diagnosis of human immunodeficiency virus. Rev. Fac. Med. Hum. [online]. 2021, vol.21, n.4, pp.696-703. ISSN 1814-5469.  http://dx.doi.org/10.25176/rfmh.v21i4.4023.

Objectives:

To standardize and validate a western blot test for the diagnosis of human immunodeficiency virus.

Methods:

A prospective observational study was carried out during 2017 and 2018. The western blot test was standardized, using the polyacrylamide gel electrophoresis technique with sodium dodecyl sulfate (SDS PAGE), being the nitrocellulose blot strips prepared with an Optimal HIV-1 antigen concentration of 2.71 µg / mm. The western blot was validated in the laboratory against 400 reference samples (300 sera and 100 plasmas): 200 positive and 200 negatives for antibodies against HIV-1, being the reference test the Immunoblot of the Fujirebio brand. Diagnostic performance parameters were estimated using Epidat v3.1 and Excel.

Results:

Eight important bands of the HIV-1 antigen were identified: p17, p24, p31, p39, gp41, p55, p66, and gp120. According to the Consortium for the normalization of serology for retroviruse, those that were taken as specific diagnostic bands were: p24, p31, gp41, and gp120. The sensitivity, specificity, positive and negative predictive value and validity index against sera were: 96.7%, 96.0%, 96.0%, 96.6%, 96.3%; and against plasmas: 98.0%, 100.0%, 100.0%, 98.0%, 99.0% respectively. No false positives and negatives were found, but some were undetermined.

Conclusion:

The development of this western blot test with proprietary technology presented similar diagnostic performance to the reference test, without showing cross-reactions, being useful for confirming HIV.

Palavras-chave : Western Blotting; HIV; Diagnosis; Sensitivity and Specificity (Source: MeSH NLM)..

        · resumo em Espanhol     · texto em Espanhol | Inglês     · Inglês ( pdf ) | Espanhol ( pdf )